> For clean Markdown of any page, append .md to the page URL.
> For a complete documentation index, see https://docs.secondsilicon.ai/llms.txt.
> For AI client integration (Claude Code, Cursor, etc.), connect to the MCP server at https://docs.secondsilicon.ai/_mcp/server.

# Troubleshooting

> Common setup, import, model, and session issues

Use this page when something blocks setup or a debug session. If a check below doesn't unblock you, include the project type, operating system, Symbiote version (if relevant), and the visible error message when you contact support.

## Scope not detected

Work through these in order:

* Confirm [Symbiote](./link) is installed and paired with the web app.
* Confirm the device is a PicoScope 2204A. Manual measurement entry still works without supported hardware.
* Install PicoScope 7 or the required PicoSDK components for your OS.
* Connect the scope directly over USB. Skip hubs while you're chasing detection issues.
* Open PicoScope 7 once and confirm it sees the device, then quit it so it releases the device before Symbiote tries to connect.
* On Apple Silicon Macs, if your scope driver needs Rosetta, install it with `softwareupdate --install-rosetta` and restart Symbiote.

## KiCad import fails or the schematic doesn't render

Most KiCad import problems are project-folder structure issues.

* From **New Project → Import Project**, select the folder containing the `.kicad_pro` and related `.kicad_sch` files.
* If the selected folder contains several nested `.kicad_pro` roots, select the narrower project folder unless you want several boards.
* Keep sibling sheets, libraries, library tables, and project settings inside the selected folder.

If the import succeeds but the schematic looks incomplete, save the project with a supported KiCad version and import the complete folder again.

## Altium import fails

Second Silicon expects an Altium project folder, not a standalone file or ZIP archive.

* Include the `.PrjPcb` project file.
* Include the related `.SchDoc` files and any project-side library references.
* Don't upload a single `.SchDoc` or `.PcbDoc` — single-file Altium imports aren't supported.
* Select the folder that contains one project root. Folders with zero or several `.PrjPcb` roots are rejected.

## Agent responses are slow or time out

Slow responses usually come from a large context, provider latency, or a network issue.

* Start a new thread if the current one has a long history or many attached files.
* Remove irrelevant firmware attachments or schematic selections before asking a new question.
* Pin a faster model from the composer.
* Check corporate proxy, VPN, or firewall rules if requests fail consistently.

## BYOK key rejected

When a provider key doesn't work:

* Confirm the key belongs to the provider field where you pasted it.
* Confirm your provider account has access to the model you selected.
* Check account balance, billing status, and usage limits with the provider.
* Rotate the key in the provider console and paste the new one under **Settings → API Keys**.
* Enable at least one model from that provider under **Settings → Models**.